weight per sqft of composite decking

floor deck catalog - ASC Steel Deck

Least steel weight per square foot floor deck. Meets SDI 2x12 inch standard profile requirements. Reduced composite slab depth compared to. 3WxH-36 and NH-32. composite deck. 2 inch nominal depth, 36 inch coverage. 9 foot to 13 foot Optimal Span Range. Pan perforated Acustadek? Option (Available with. Smooth Series? rivet attachments or welded). Aesthetic flat pan underside. Meets SDI 2x12 inch standard profile requirements. Reduced composite slab depth  【Get Price】

Metal Decking Design Guide - New Millennium Building Systems

4 1/2. 5. 28 Gage. 26 Gage. 24 Gage. 22 Gage. Notes. 1. Section properties are calculated using the. AISI Cold Formed. Steel Design. Specifications, 1996. Edition. 2. Loads and maximum construction spans are based on the SDI. Design Manual for. composite Decks,. Form Decks and Roof. Decks, Publication. No. 30. 3. Minimum interior bearing length shall be 3". Minimum exterior bearing length shall be 1 1/2". Total. Slab. Concrete. Concrete. Depth. weight. weight. (in.) (psf). (psf). 【Get Price】

Vulcraft Roof Catalog/REV2 - Civil, Environmental and Architectural

TECHNICAL PRODUCT INFORMATION. ROof. NON-composite. composite. 1.0E. 1.5A. 1.5F. 1.5B, 1.5BI, 1.5BA, 1.5BIA. 3N, 3NI*, 3NA, 3NIA*. 0.6C and 0.6CSV**. 1.0C and 1.0CSV*. 1.3C and 1.3CSV. 1.5C. 2C. 3C. 1.5VL and 1.5VLI SECTION PROperTIES. Deck. Design. weight (PSF). I. Sp. Sn. Fy. Type. Thick. Ptd. Galv. in4/ft in3/ft in3/ft. KSI. B24. 0.0239. 1.36. 1.46. 0.121. 0.120. 0.131. 60. B22. 0.0295. 1.68. 1.78. 0.169. 0.186. 0.192. 33. B21. 0.0329. 1.87. 1.97. 0.192. 【Get Price】

deck products - Bushwick Metals

If these minimum lengths are not provided, web crippling must be checked. - Section properties calculated in accordance with. AISI specifications. Section Properties (Fy=40 ksi). Helpful Hint: 1 1/2” composite deck is used when the slab and support to support distance are both moderate in size. 30” Cover and Integral Hangar Tabs also available. 36” Cover. Total Slab Thickness. 1 1/2”. 2 1/2”. 6”. Slab. Max Unshored. Superimposed Live Load in Pounds per Square Foot. DepthGage. 【Get Price】

Composite Deck On Bushwick Metals, LLC

Results 1 - 10 of 10 Browse composite Deck in the Bushwick Metals, LLC catalog including Item #,Item Name,Thickness,weight per Sq. Ft. 【Get Price】

Weights of Building Materials – Pounds Per Square Foot [PSF]

ROof. Fiberglass shingles. 3. Asphalt shingles (1). 2. Wood shingles (1). 3. Spanish clay tile (1). 19. Concrete roof tile. 12. Composition Roofing: Three-ply ready roofing (1). 1. Four-ply felt and gravel (1). 5.5. Five-ply felt and gravel (1). 6. 20 gage metal deck (1). 2.5. 18 gage metal deck (1). 3. 0.05” thick polyvinyl chloride polymer membrane(4). 0.35. 1" fiberglass batt insulation. 0.04. 1" loose fiberglass insulation. 0.04. 1" loose cellulose insulation. 0.14. 1" rigid insulation (1). 1.5. 【Get Price】

Calculate Deck Load Capacity - Tributary Area - DecksGo

To determine the maximum load capacity of your deck, start by calculating its total area and multiply by 50 psf. So a 100 sqft deck would be designed to support 5000 lbs. Don't get confused with what weight you might think or want to load the deck with. If you drove a dump truck over it, yes this would throw all our calculations out the window. But we are building a deck to support known loads consistent with the purpose for which the structure is known to be used for and the 50 psf  【Get Price】